Essick 336-500 User Manual

Browse online or download User Manual for Humidifiers Essick 336-500. Essick Humidifier 336-500

  • Download
  • Add to my manuals
  • Print
  • Page
    / 53
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
L
U
®
C
Printed in U.S.A
READ AND SAVE THESE INSTRUCTIONS
586 4160 Rev. 4/04
L
U
®
French and Spanish
instructions included.
Se incluyen instrucciones
en Español y Francés.
Directives en français et
en espagnol comprises.
Evaporative
Humidifier
OWNERS
CARE
&
USE
MANUAL
Model:
338 000 3-speed Multiroom
Evaporative Humidifier with
Removable Water Bottles
and AirCare
®
Filter
SAVE THE ENVIRONMENT
RECYCLE APPROPRIATE MATERIALS
Patents: 5,037,583; 5,110,511; 5,133,904
Other Patents Pending
To order parts and accessories call 1-800 547-3888
336 500 3-speed Multiroom
Evaporative Humidifier with
Removable Water Bottles
and no AirCare
®
Filter
Page view 0
1 2 3 4 5 6 ... 52 53

Summary of Contents

Page 1 - Humidifier

LU®CPrinted in U.S.AREAD AND SAVE THESE INSTRUCTIONS586 4160 Rev. 4/04LU®French and Spanishinstructions included.Se incluyen instruccionesen Español

Page 2 - Important Safeguards

5) Install new wicks and clean the humidifier before next season begins.Use only Bemis by Essick Air evaporative wicks to ensure the manufac-turer’s r

Page 3 - Tips for Best Performance

• If the water valve leaks around the rubber stopper after filling, emptythe water bottle and inspect the stopper. Mineral particles may pre-vent full

Page 4 - Controls and Operation

AccessoriesEVAPORATIVE WICKModel 1040 (contains two wicks) Replaceable evaporative wicks continuouslydraw up moisture as they filter out mineraldeposi

Page 5 - (one on each side)

HOME COMFORT DIVISION ONE-YEAR LIMITED WARRANTYThe Bemis by Essick Air humidifier warranty covers defects in materials and workman-ship for a period o

Page 7 - DISINFECTING UNIT

No. 1970Bacteria Treatment, 32 oz.$5.99• Helps Eliminate Bacteria & Algae Build-up• Strongly Recommended for Bemis Humidifiers& All Other Evap

Page 9 - END-OF-SEASON MAINTENANCE

LU®CPrinted in U.S.ALEER Y CONSERVAR ESTAS INSTRUCCIONESLU®French and Spanishinstructions included.Se incluyen instruccionesen Español y Francés.Direc

Page 10 - Troubleshooting

Pautas de Seguridad ImportantesLEER ANTES DE UTILIZAR EL HUMIDIFICADOR1. Este artefacto tiene un enchufe polarizado (una espiga es más anchaque la otr

Page 11

IntroducciónEste humidificador está diseñado para aliviar la incomodidad del aire secoen ambientes de área reducida (hasta 1100 pies2 / 102 m2) donde

Page 12 - Accessories

Important SafeguardsREAD BEFORE USING YOUR HUMIDIFIER1) This appliance has a polarized plug (one blade is wider than the other).To reduce the risk of

Page 13 - Essick Air Products, Inc

5. Cambiar las mechas vaporizadoras por lo menos una vez al año. Enáreas de agua extremadamente dura, puede ser necesario cambiarlascon más frecuencia

Page 14

6. Retirar una botella de agua, observar su tapa (A), y ubicar el mecanismo del vástago de laválvula (B). La tapa se puede sacar para llenar la bote-l

Page 15 - ACCESSORY ORDER FORM

11. Regresar las botellas a su posición correcta usando las asas de la partesuperior. Colocar lentamente lasbotellas en la hendidura en el fondodentro

Page 16

LIMPIEZA DE LA BANDEJA Y REEMPLAZO DE LASMECHAS (MODELO #1040)CUIDADO: Desconectar la corriente eléctrica antes de limpiar ode darle servicio a la uni

Page 17 - DE CUIDADO

ELIMINACIÓN DE CALCIFICACIONES5. Retirar las dos mechas vaporizadoras de agua de la ban-deja permitiendo así el drenaje delexceso de agua hacia la ban

Page 18

14. Colocar la bandeja con las flechas en el interior de la bandeja apuntan-do hacia usted. Asegurarse que las perillas de control queden mirandohacia

Page 19 - Rendimiento

1. Apagar la unidad y desenchufar el cable.2. Retirar las botellas de agua delhumidificador y echarlas de espal-da en un lugar seguro.3. Separar la se

Page 20 - Controles y Operación

4. Almacenar en un lugar fresco y seco.5. Instalar mechas vaporizadoras nuevas y limpiar el humidificador antesde que comience la siguiente temporada.

Page 21 - (uno a cada lado)

4. El agua no fluye de las botellas:• Después de llenar las botellas de agua y de colocarlas en el humidi-ficador, puede ser que el agua no fluya si e

Page 22 - Cuidado y Mantenimiento

AccesoriosMECHA VAPORIZADORAModelo 1040 (contiene dos mechas).Las mechas vaporizadoras reemplazables generanhumedad continuamente a la vez que filtran

Page 23 - MECHAS (MODELO #1040)

IntroductionThis humidifier is designed to provide relief from dry air discomfort in local-ized areas, such as bedrooms, dens and other rooms for a to

Page 25 - AIRE (MODELO #1053)

DIVISIÓN DE CONFORT PARA EL HOGARGARANTÍA LIMITADA DE UN AÑOLa garantía del Humidificador Bemis by Essick Air cubre defectos de materiales y de manode

Page 27 - Diagnóstico de Problemas

No. 1970Bactericida, 946ml (32 Onz.)$ 5.99- Ayuda a Eliminar la Bacteria y la Aacumulación de Algas.- Se Recomienda para los Humidificadores Bemis y T

Page 29 - Accesorios

Imprimé aux É.-U.LU®CLU®French and Spanishinstructions included.Se incluyen instruccionesen Español y Francés.Directives en français eten espagnol com

Page 30

Mesures de sécurité importantesÀ LIRE ATTENTIVEMENT AVANT D'UTILISER L'HUMIDIFICATEUR.1- Cet appareil est muni d'une fiche polarisée (u

Page 31

IntroductionCet humidificateur est conçu pour fournir un soulagement des malaisescausés par l’air sec dans des endroits particuliers où il y a un beso

Page 32

4- Remplacer régulièrement les Filtres à air Air Care®, de préférence, unefois l'an.5- Changer les filtres à mèche d'évaporation au moins un

Page 33 - Total de la factura

5- Ce modèle est également muni d’un hygrostat automatique. (Le boutonde réglage de l’hygrostat est situé à gauche.) L’hygrostat met l’humidifi-cateu

Page 34

7) Do not use water treatment products designed for Water Wheel,Rotobelt, drum type, or ultrasonic humidifiers. These products may causethe wicks to b

Page 35 - D'ENTRETIEN

10- Pour ajouter de l'eau, placer un chiffon doux au fond de l’évier etmettre un récipient d’eau sur le chif-fon. Faire couler le robinet d’eaufr

Page 36

Soins et EntretienLes humidificateurs fournissent le confort en ajoutant de l'humidité à l'air secd'une pièce chauffée. Afin de tirer u

Page 37 - Des trucs pour un meilleur

DÉTARTRAGE5- Retirer les deux filtres à mèche de la base en laissant l'excès d'eaus'écouler dans le plateau. Ne rincerles filtres à mèc

Page 38 - Réglage et Fonctionnement

14- Il faut placer le plateau de façon à ce que les flèches intérieures soientdirigées vers soi. En s'assurant que les boutons de réglage soient

Page 39 - (un de chaque côté)

1- Fermer l'appareil et le débrancher.2- Retirer les récipients d'eau del'humidificateur et les déposer surle dos.3- Retirer le couverc

Page 40

5- Installer de nouveaux filtres à mèche et nettoyer l'humidificateur avant ledébut de la saison suivante. N'utiliser que les filtres à mèch

Page 41 - Soins et Entretien

4- L'eau ne s'écoule pas des récipients d'eau :• Après avoir rempli les récipients d'eau et les avoir remis dans l'hum-idific

Page 42 - RÉ-ASSEMBLAGE

AccessoiresFILTRE À MÈCHE D'ÉVAPORATIONModèle no: 1040 (Comprend deux filtres à mèche).Filtres à mèche remplaçables qui tirent continuelle-ment l

Page 43 - (MODÈLE NO : 1053)

DIVISION DU CONFORT À LA MAISONGARANTIE LIMITÉE DE UN AN La garantie sur l'humidificateur Bemis by Essick Air porte sur tous défauts dans lamati

Page 44 - ENTRETIEN EN FIN DE SAISON

No : 1970Traitement contre les bactéries, 946 mL (32 oz) 5,99 $* Favorise l’élimination de la prolifération d’algues et de bactéries.* Fortement recom

Page 45 - Guide de dépannage

7) Before proceeding, make sure the wicks are resting all the way into the water channel(see diagram). Refer to the CARE ANDMAINTENANCE section for in

Page 47 - Accessoires

Authorized Repair and Service StationsFor a list of service stations authorized to make both in-warranty andout-of-warranty repairs to Bemis by Essick

Page 49

Essick Air Products, Inc.5800 Murray StreetLittle Rock, AR 72209501.562.1094

Page 50

Caution: Under certain conditions, cold objects in the room, suchas windows and outside walls, may cause moisture to con-dense. Severe condensation on

Page 51 - Phone: 800-547-3888

REMOVING SCALE5) Remove the two evaporative water wicks from the tray allowing excesswater to drain into the tray. Rinsethe wicks under fresh water on

Page 52

RE-ASSEMBLY12) Replace the wicks into the tray water channel. See CONTROLS ANDOPERATION section.13) Replace the air filters (if provided) in the inlet

Page 53

1) Turn the unit off and unplugthe cord.2) Remove the water bottles from thehumidifier and lay bottles on theirbacks.3) Remove the top housing from th

Comments to this Manuals

No comments